Monday, January 7, 2013

WT-1010C2 GSM Terminal Use As Backup For Landline In The Alarm System


Usually, the alarm panel in the market will use telephone line (landline) as the main alarm communicators to sent the alarm signal to the police, house owner, center monitoring station if any alarm trigger because of intruded or sabotage.

Witura’s WT-1010C2 GSM alarm backup system can connect to any panel likes Texecom, Pyronix, Securit as the alarm backup. If any landline is been cut by intruder or faulty, the gsmdialleror alarm communicators must be intelligent enough to identified the line cut and sent out the alarm signal to the police, house owner and alarm receiving center (ARC)   - As the backup alarm

This GSM communicator is important to use in the places likes Banking, ATM machines, jewelry shop, notebook house and etc where double protection on properties is required

The cellular backup WT-1010C2 alarm communicators or GSM dialler inbuilt the audible data transferring protocols likes Contact ID, SIA, ADEMCO into the unit and ensure all the security protocol format can be transmitted to the center monitoring station.

The ideas for the for the GSM communicator or backup alarmshould perform the following ;

Use as the telephone line backup in alarm system - Phone lines can easily be cut off during storms, construction work, accidents, or even deliberate tampering by intruders. GSM Cellular or GSM module for alarm WT-1010C2 will checks the status of the telecom line in the alarm panels likes Paradox, DSC, Honeywell and in case the telecom line become unavailable, the GSM module for alarm -  WT-1010C2 will transmit the alarm using GSM to the alarm receiving center (ARC) or Center Monitoring Station (CMS)

The unit should have standby recharger battery to prevent power failure or electricity cut off by intruded. The GSM will function as normal when no electricity supply. LCD display to check the GSM signal strange and battery capacity

Auto self-check and restart function is important: The unit should continuously monitor the system status of its own. When there is a problem with the SIM card or the backup alarm is not working properly, it will automatically restart the system.

The GSM module for alarm should automatically call to 8 pre-program phone numbers while alarming. The gsmdiallershould SMS to 8 programmable cell phone number to notify the user that the PSTN line has been cut off or unavailable

In order prevent professional thief tries to disconnect GSM by using “GSM Jammer”, WT1010C2 gsm alarm backup will transmit the contact ID using telecom line if GSM signal drop immediately and trigger the siren.

The unit should also be low power consumption –GSM communicator or GSM module for alarm uses 30mA while in idle state and 260mA when transmitting an alarm to prevent backup battery finish.
Auto Test Reporting System is important - After the programmed reporting time, the cellular backup WT-1010C2 GSM Cellular should dial the programmable center station number. Once the call is connected, it will transmit the programmable contact-id to the central station and hang up. This function is to make sure that “GSM alive” daily and able to report to ARC if any emergency.

Programmable Contact ID – The cellular backup WT-1010C2 GSM dialerhas built-in alarm inputs that allow the unit to send additional signals (with user programmable Contact-ID event) to the monitoring station. Supported Protocol Pager message (DTMF no handshake)

Three Remote Controlling Outputs in the GSM module for alarm - These open collector outputs (that can sink max 300MA per output) can be turned on and off remotely through a SMS. You can use them to pull to ground your inputs. Remote control alarm communicators will be reachable by sending a SMS with a certain command. For example, switch on lighting, air conditional, or switch off generator, sensor using your mobile phone.

Three Digital Inputs - The system has the function to send alert message to the user in the event of input triggered at GSM module for alarm. For example, Zone 4 connected to an electrical door, when there is intruder or electrical door is open illegally, GSM Cellular WT-1010C2 alarm backup will receive short circuit impulse on Zone 4 and automatically send a signal to the monitoring station and notify the owner. It is possible to enable or disable the function by sending the SMS command to the unit.

Input alarm message can be edited and programmed up to 50 characters long. You can use this function to program any languages. You can change the displayed text by sending a command by SMS to the GSM communicators.

Permanent +V Output Facility – This output is available and ground on the main board of the GSM cellular. The output voltage is according to power supply and it can be used to power on other facility or device.

Wall mounting enclosure available: The GSM Cellular WT-1010C2 backup alarm units can be installed inside the alarm panel or inside its own wall mount enclosure.

Read more about us and discover the amazing array of our products. For more information please visit us at http://www.witura.com/products/security-industry/gsm-terminal-use-as-backup-for-landline-in-the-alarm-system.html
 Those interested in contacting with the Witura and want to know more information about the WT-10101C2 can also email to sales@witura.com