Sunday, December 30, 2012

GSM Terminal Use For Alarm System (Model: WT-1010C2)




Usually, the alarm panel in the market will use telephone line (landline) as the main alarm communicators to sent the alarm signal to the police, house owner, center monitoring station if any alarm trigger because of intruded or sabotage.
Witura’s WT-1010C2 GSM alarm backup system can connect to any panel likes Texecom, Pyronix, Securit as the alarm backup. If any landline is been cut by intruder or faulty, the gsmdialleror alarm communicators must be intelligent enough to identified the line cut and sent out the alarm signal to the police, house owner and alarm receiving center (ARC)   - As the backup alarm
This GSM communicator is important to use in the places likes Banking, ATM machines, jewelry shop, notebook house and etc where double protection on properties is required
The cellular backup WT-1010C2 alarm communicators or GSM dialler inbuilt the audible data transferring protocols likes Contact ID, SIA, ADEMCO into the unit and ensure all the security protocol format can be transmitted to the center monitoring station.
The ideas for the for the GSM communicator or backup alarmshould perform the following ;
Use as the telephone line backup in alarm system - Phone lines can easily be cut off during storms, construction work, accidents, or even deliberate tampering by intruders. GSM Cellular or GSM module for alarm WT-1010C2 will checks the status of the telecom line in the alarm panels likes Paradox, DSC, Honeywell and in case the telecom line become unavailable, the GSM module for alarm -  WT-1010C2 will transmit the alarm using GSM to the alarm receiving center (ARC) or Center Monitoring Station (CMS)
The unit should have standby recharger battery to prevent power failure or electricity cut off by intruded. The GSM will function as normal when no electricity supply. LCD display to check the GSM signal strange and battery capacity
Auto self-check and restart function is important: The unit should continuously monitor the system status of its own. When there is a problem with the SIM card or the backup alarm is not working properly, it will automatically restart the system.
The GSM module for alarm should automatically call to 8 pre-program phone numbers while alarming. The gsmdiallershould SMS to 8 programmable cell phone number to notify the user that the PSTN line has been cut off or unavailable
In order prevent professional thief tries to disconnect GSM by using “GSM Jammer”, WT1010C2 gsm alarm backup will transmit the contact ID using telecom line if GSM signal drop immediately and trigger the siren.
The unit should also be low power consumption –GSM communicator or GSM module for alarm uses 30mA while in idle state and 260mA when transmitting an alarm to prevent backup battery finish.
Auto Test Reporting System is important - After the programmed reporting time, the cellular backup WT-1010C2 GSM Cellular should dial the programmable center station number. Once the call is connected, it will transmit the programmable contact-id to the central station and hang up. This function is to make sure that “GSM alive” daily and able to report to ARC if any emergency.
Programmable Contact ID – The cellular backup WT-1010C2 GSM dialerhas built-in alarm inputs that allow the unit to send additional signals (with user programmable Contact-ID event) to the monitoring station. Supported Protocol Pager message (DTMF no handshake)
Three Remote Controlling Outputs in the GSM module for alarm - These open collector outputs (that can sink max 300MA per output) can be turned on and off remotely through a SMS. You can use them to pull to ground your inputs. Remote control alarm communicators will be reachable by sending a SMS with a certain command. For example, switch on lighting, air conditional, or switch off generator, sensor using your mobile phone.
Three Digital Inputs - The system has the function to send alert message to the user in the event of input triggered at GSM module for alarm. For example, Zone 4 connected to an electrical door, when there is intruder or electrical door is open illegally, GSM Cellular WT-1010C2 alarm backup will receive short circuit impulse on Zone 4 and automatically send a signal to the monitoring station and notify the owner. It is possible to enable or disable the function by sending the SMS command to the unit.
Input alarm message can be edited and programmed up to 50 characters long. You can use this function to program any languages. You can change the displayed text by sending a command by SMS to the GSM communicators.
Permanent +V Output Facility – This output is available and ground on the main board of the GSM cellular. The output voltage is according to power supply and it can be used to power on other facility or device.
Wall mounting enclosure available: The GSM Cellular WT-1010C2backup alarmunits can be installed inside the alarm panel or inside its own wall mount enclosure.
Read more about us and discover the amazing array of our products. For more information please visit us at http://www.witura.com/products/security-industry/gsm-terminal-use-as-backup-for-landline-in-the-alarm-system.html
 Those interested in contacting with the Witura and want to know more information about the WT-10101C2 can also email to sales@witura.com

Monday, September 17, 2012

Fully Automatic GSM Remote Water Tank Level Monitoring and Pump Control System


A dynamic hydro or water level management system that thrives on changes and turns variations to your advantage. The device should provide convenience and peace of mind as owners do not need to be present at all times on site to monitor water levels at different sectors.”

The ideas remote water level management and control system should perform the following;  

1)      When water down to certain level – “LOW” , 1st input sensor should detect, the WT-1011RC will trigger input and sent SMS to 8 persons mobile phone (admin) including the monitoring software in office. For example, SMS inform users – “TANK 1 Water LOW”

2)      The 2nd input will detect the second level of water – “CRITICAL LOW”. When 2nd sensor detect the level which reach the minimum, it will trigger the 2nd input, WT-1011RC will then sent message to the water pump, turn on the water pump.

3)      When the water pump turns on, it will sent out the SMS to the user to inform the water pump turn on/ off. For example – SMS contents “Water Pump 1 turn on”

4)      After the pump turns on and water level up to the maximum level, sensor will trigger WT-1011RC and sent the SMS to the water pump, to turn off the water pump. WT-1011RC will then report the SMS to user – “water pump turn off”

5)      If outside the dam water level is higher, dam electric gate should be shut off to prevent water flow back. WT-1011RC will trigger the door gate motor turn on and closed the gate, send a message to the users. “Door Closed, Water Level High”

6)      If outside the dam water level became lower, WT-1011RC will trigger the door gate to open, send a message to user or remote monitoring software.

7)      Every time when switch on / off, level high, low, back to normal, turn off pump, it will send SMS to the user. 

Whenever variations of weather conditions are present such as drought, rain or tide changes, it will affect the water levels. GSM remote monitoring and control system should detect the water level and sent to 8 people’s mobile phone (admin) and remote monitoring software provided.

The GSM alert system provides convenience and peace of mind as owners do not need to be presents at all the times or employs a person sitting at site to monitor water levels at different sectors.

Another function for the GSM remote control system is used to protect the pump motor from excessive wear and tear leading to pre-mature failure. Heat is generated when electric motors operate. The pump motors require additional power upon start up to accelerate the pump and begin moving the water. This additional power (cold cranking amps) generates extra heat.  WT-1011RC is able to detect when overhead and SMS the user and remote monitoring software.

For more queries, please contact sales@witura.com or view the video presentation at http://www.witura.com/img/water_tank_management_and_control_system.swf  

Monday, August 6, 2012

GSM Remote Control Switch For Rental & Leasing Hire Equipment


The “Off Hire” Model WT 215 has been specifically designed for the construction equipment hire industry to allow the owner to have remote control over the equipment regardless of the location of the equipment.
In many examples, the remote location of the equipment does not allow the owner to ensure that they are being honestly informed when the equipment is actually off hire and is continued to be used after it has been claimed to be off hire

This is cost the owner valuable revenue and the Off Hire system ensures the owner can remotely disable the equipment when it has been claimed to be Off service and not being paid for

In the same situation, the owner can re enable the equipment if is further required and this can be done remotely from any location and regardless of the location of the equipment or the owner 

This is a simple “low cost solution, and done very simple via the GSM network using your mobile phone which can “disable” and Enable” anytime by sending the text messages to the construction equipment.  The system can also advise the owner if the power to equipment has been disconnected and also when it is reconnected.

The off hire system also has an alarm input which can monitor one of the more critical parameters of the construction equipment which may cause serious damage to the unit such as overheating or lower water pressure to the system and again the unit can be shut down remotely to prevent any further damage


The off hire system is housed in an IP 65 enclosure and supplied with two compression glands and has fixing points to secure the system to any part of the construction equipment and can also remain covert without any unauthorized parties aware of the face the system is installed.